The Zhu-Lu formula: a machine learning-based intraocular lens power calculation formula for highly myopic eyes

Abstract

Background

To develop a novel machine learning-based intraocular lens (IOL) power calculation formula for highly myopic eyes.

Methods

A total of 1828 eyes (from 1828 highly myopic patients) undergoing cataract surgery in our hospital were used as the internal dataset, and 151 eyes from 151 highly myopic patients from two other hospitals were used as external test dataset. The Zhu-Lu formula was developed based on the eXtreme Gradient Boosting and the support vector regression algorithms. Its accuracy was compared in the internal and external test datasets with the Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Kane, Pearl-DGS and Radial Basis Function (RBF) 3.0 formulas.

Results

In the internal test dataset, the Zhu-Lu, RBF 3.0 and BUII ranked top three from low to high taking into account standard deviations (SDs) of prediction errors (PEs). The Zhu-Lu and RBF 3.0 showed significantly lower median absolute errors (MedAEs) than the other formulas (all P < 0.05). In the external test dataset, the Zhu-Lu, Kane and EVO 2.0 ranked top three from low to high considering SDs of PEs. The Zhu-Lu formula showed a comparable MedAE with BUII and EVO 2.0 but significantly lower than Kane, Pearl-DGS and RBF 3.0 (all P < 0.05). The Zhu-Lu formula ranked first regarding the percentages of eyes within ± 0.50 D of the PE in both test datasets (internal: 80.61%; external: 72.85%). In the axial length subgroup analysis, the PE of the Zhu-Lu stayed stably close to zero in all subgroups.

Conclusions

The novel IOL power calculation formula for highly myopic eyes demonstrated improved and stable predictive accuracy compared with other artificial intelligence-based formulas.

Background

Modern cataract surgery has shifted to more of a refractive procedure [1, 2]. Currently, intraocular lens (IOL) power calculations have undergone continuous refinement, and improved outcomes have been reached in normal eyes using the newer generation formulas [3, 4]. However, due to the extreme axial length (AL) elongation and complicated ocular biometric characteristics [5], accurate IOL power prediction in highly myopic eyes remains a significant challenge.

Techniques using artificial intelligence (AI) have been applied to improve the accuracy of IOL power calculations. The AI-based formulas, such as Emmetropia Verifying Optical (EVO), Kane, Ladas, Pearl-DGS, Radial Basis Function (RBF) 3.0 and Sramka formulas were recently introduced and have achieved better predictability [2, 6,7,8,9]. The Barrett Universal II (BUII) formula has been around for a longer time [10] and have so far showed promising results and is widely used because of its availability on biometers [11].

However, when used on highly myopic eyes, there are still some inaccuracies. On the one hand, these formulas were derived from training datasets of the Caucasian eyes with a whole AL range, which compromised relatively small percentages of highly myopic eyes due to the lower prevalence of high myopia in western countries [12]. Unexpected refractive surprise may still become a problem when applying the existing AI-based formulas to highly or extremely myopic eyes [13, 14]. On the other hand, some of these formulas have maximum AL input limits and target refraction limits. For example, the Kane and RBF 3.0 formulas have maximum input limits of 35.00 mm on the AL, and the target refraction for the RBF 3.0 formula is restricted from − 2.50 D to 1.00 D, suggesting these may not have considered patients with high or extreme myopia who will require good near vision. Therefore, there is a critical need to develop an AI-based formula with significantly improved accuracy exclusively designed for highly myopic eyes.

The eXtreme Gradient Boosting (XGBoost) and support vector regression (SVR) are two popular and widely used machine learning models that provide applications in data classification and regression [15, 16]. The former derives from the gradient boosting decision tree and is recognized as highly efficient, portable and scalable [15]. The latter uses the principle of the support vector machine method, featured by its robustness and accuracy in data prediction [16]. Using these two models, we developed a novel IOL power calculation formula exclusively for refractive prediction in highly myopic eyes, and compared its performance with the BUII, EVO 2.0, Kane, Pearl-DGS and RBF 3.0 formulas.

Methods

The study was approved by the Institutional Review Board of the Eye & Ear, Nose, and Throat (ENT) Hospital of Fudan University (ID: 2020005). Written informed consent was obtained from all participants for the use of their clinical data. All procedures adhered to the tenets of the Declaration of Helsinki.

Subjects

High myopia was defined as AL ≥ 26.00 mm. The internal dataset was collected from the Eye & ENT Hospital of Fudan University from Jan 2019 to Aug 2021, and the external test datasets were collected from the Shanghai Aier Eye Hospital and the Eye Hospital of Wenzhou Medical University. Highly myopic eyes undergoing uneventful cataract surgeries with IOL implantation were reviewed. Eyes with complete preoperative biometric data and credible postoperative (one to two months after surgery) manifest refraction outcomes were included. Postoperative subjective refractive outcomes were assessed by a licensed optometrist and best corrected vision acuity was assessed at 5 m. Then, the refractions were standardized to a 6 m distance by adding − 0.03 D to the spherical equivalent. One eye was randomly selected if both eyes met the criteria. The exclusion criteria were eyes with postoperative best-corrected distance visual acuity (BCVA) less than 20/40, severe corneal opacity or other ocular diseases that may influence the accuracy of manifest refraction, and history of ocular trauma or surgery. In total, 1828 highly myopic eyes of 1828 patients were included in the internal dataset, and 151 highly myopic eyes of 151 patients were included in the external test dataset.

The complete preoperative biometric data included AL, flattest and steepest keratometry (K) values, anterior chamber depth (ACD, as measured from corneal epithelium to the lens), lens thickness (LT), and horizontal corneal diameter (CD), which were all measured by IOLMaster 700 (version 1.50, Carl Zeiss Meditec AG, Jena, Germany). In the internal dataset, the implanted IOL types included data obtained from the Tecnis ZCB00 (33 cases), Tecnis ZA9003 (29 cases), Zeiss CT ASPHINA 409MP (353 cases), Alcon SN60WF (34 cases), HumanOptics MC X11 ASP (658 cases), HumanOptics ASPIRA-aAY (39 cases), Rayner 920H (646 cases), and Ophtec B.V. 52501TW/TY (36 cases). In the external test dataset, the implanted IOL types included data from the Alcon SN6CWS (33 cases), Alcon SN60WF IQ (63 cases), Bausch & Lomb Akreos AO MI60 (28 cases), HumanOptics ASPIRA-aAY (7 cases), and Zeiss CT ASPHINA 509 M (20 cases). “A constants” were obtained from the IOL Con website (www.iolcon.org) [46] for each IOL type, as advised by Professors Hoffer and Savini [17].

Dataset preparation

The internal dataset was randomly split into training dataset and internal test dataset with a fixed ratio (8:2, 1462 eyes in the training dataset and 366 eyes). The machine learning features used can be classified into three categories: (1) ocular biometrics: AL, flattest and steepest K values, ACD, LT, and CD; (2) IOL information: implanted IOL power and A constants suggested by the IOL Con website for each IOL type; (3) parameters after transformations: predicted refractions calculated by the Haigis and the SRK/T theoretical formulas [18, 19].

Modeling

The training dataset consisted of 1462 highly myopic eyes with complete information that was used for modeling. After a series of attempts at feature selection and combination, we constructed two sets of learning features. In addition to all ocular biometric features and all IOL information features, feature set 1 incorporates results from the Haigis and SRK/T formulas, while feature set 2 only contains results from the Haigis formula. Two supervised learning models, i.e., the XGBoost and the SVR, were trained with each of the two sets of learning features. The actual postoperative manifest refraction (presented as spherical equivalent [SE]) was set as the training target. Therefore, we obtained four sub-models, each of which can function independently for IOL power calculation in highly myopic eyes. To increase the model robustness, we adopted the weighted average of the calculation results from four sub-models and generated an assembled prediction model. Figure 1 shows the flow diagram of the model construction. Based on this assembled model, we built a novel IOL power calculation formula, named the Zhu-Lu formula (IOL power calculation formula for highly myopic eyes developed by Zhu and Lu). The software used in model construction was Python 3.7 with the scikit-learn package.

Fig. 1
figure 1

The flow diagram of model construction. In addition to all ocular biometric features and all IOL information features, feature set 1 incorporates results from the Haigis and SRK/T formulas, while feature set 2 only shows results from the Haigis formula. AL, axial length; CD, horizontal corneal diameter; LT, lens thickness; ACD, anterior chamber depth; IOL, intraocular lens; XGBoost, eXtreme Gradient Boosting; SVR, support vector regression; BUII, Barrett Universal II; EVO, Emmetropia Verifying Optical; RBF, Radial Basis Function; SD, standard deviation; PE, prediction error; D, diopter; MAE, mean absolute error; MedAE, median absolute error

Evaluation

The internal and external test datasets consisted of 366 and 151 highly myopic eyes, respectively. Due to the restriction of AL input (up to 35.00 mm) of the Kane and RBF 3.0 formulas, five cases in the internal test dataset and one case in the external test dataset were further excluded from analysis. The remaining 361 and 150 eyes in the internal and external test datasets were used. The prediction error (PE) was calculated as the actual postoperative refraction minus the predicted refraction back-calculated with the implanted IOL power using the BUII, EVO 2.0, Kane, Pearl-DGS, RBF 3.0 and Zhu-Lu formulas (URLs: additional sources [40,41,42,43,44,45,46]). The mean absolute errors (MAEs), median absolute errors (MedAEs) and percentages of eyes within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D of the PE were calculated and compared, as well as the cumulative percentages of eyes within different absolute errors. The formula performance index for each formula was calculated following recommendations by Hoffer et al. [17] which is based on four parameters: standard deviation (SD) of the PE, MedAE, the correlation between PE and AL (evaluated by the Pearson’s correlation test), and the inverse value of the percentage of eyes within ± 0.50 D of the PE. The higher the formula performance index, the more accurate the formula. Furthermore, accuracies were compared in subgroups according to different AL ranges (26.00–28.00 mm, 28.00–30.00 mm, and ≥ 30.00 mm).

Applications

The website for the Zhu-Lu formula is currently available (URL: https://HM-ZLF.com/). Surgeons could easily calculate the optimal IOL power and predicted refraction by entering highly myopic eye’s ocular biometry data, target refraction, and IOL constants including A constant for the SRK/T formula and a0, a1, a2 constants for the Haigis formula.

Statistics

Quantitative data were expressed as means ± SD and categorical data were displayed as proportions in demographics. After data normality was assessed with the Kolmogorov-Smirnov test, the one-way ANOVA test or the Kruskal-Wallis test was performed to analyze the normally or non-normally distributed continuous variables. Categorical data from demographics were compared using the χ2 test. The Friedman test with Bonferroni correction was used to assess the differences of MedAEs among formulas. The Cochran’s Q test with Bonferroni correction was conducted for comparisons of percentages of eyes within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D of the PE among formulas. The cumulative percentages of eyes within different absolute errors were compared using the log-rank test. Correlations between AL and PEs were assessed using the Pearson’s correlation analysis. A P value of less than 0.05 was considered statistically significant. All statistical analyses were performed using SPSS (version 26.0, IBM Corp., New York, US).

Results

Characteristics

The characteristics of the training dataset as well as the internal and external test datasets are shown in Table 1. There was no significant difference in eye laterality, gender, AL, AL subgroup distribution, flattest and steepest K values, ACD, LT, CD, implanted IOL power, and postoperative BCVA between the three datasets.

Table 1 Characteristics of highly myopic eyes in the training dataset, and the internal and external test datasets

Accuracy evaluation

Table 2 demonstrates the prediction accuracy of the six IOL calculation formulas in the internal and external test datasets. In the internal test dataset, the SD values of the six IOL calculation formulas, in order of lowest to highest, were Zhu-Lu (0.46 D), RBF 3.0 (0.51 D), BUII (0.54 D), Kane (0.55 D), EVO 2.0 (0.56 D) and Pearl-DGS (0.71 D). The Zhu-Lu formula showed significantly lower MedAEs than BUII, EVO 2.0, Kane and Pearl-DGS formulas (Friedman test with Bonferroni post hoc analysis, all P < 0.05). The IOL formula performance indexes, in order of highest to lowest, were Zhu-Lu, RBF 3.0, Kane, EVO 2.0, BUII and Pearl-DGS formulas. In the external test dataset, the SD values of the six IOL calculation formulas, in order of lowest to highest, were Zhu-Lu (0.50 D), Kane (0.52 D), EVO 2.0 (0.53 D), Pearl-DGS (0.53 D), BUII (0.57 D) and RBF 3.0 (0.57 D). The Zhu-Lu formula showed significantly lower MedAEs than Kane, Pearl-DGS and RBF 3.0 formulas (Friedman test with Bonferroni post hoc analysis, all P < 0.05). As for IOL Formula Performance Indices, the Zhu-Lu formula performed similar to the BUII and EVO 2.0, but better than the RBF 3.0, Kane and Pearl-DGS formulas.

Table 2 Prediction outcomes of the BUII, EVO 2.0, Kane, Pearl-DGS, RBF 3.0 and Zhu-Lu formulas in highly myopic eyes

The distribution of the PE in both internal and external test datasets using histograms are shown in Fig. 2. In the internal test dataset, the Zhu-Lu formula showed the highest percentages of eyes within ± 0.50 D of the PE (80.61%), followed by RBF 3.0 (72.85%), BUII (62.33%), EVO 2.0 (61.22%), Kane (59.56%) and Pearl-DGS (53.19%). The BUII, EVO 2.0, Zhu-Lu and RBF 3.0 formulas had comparable percentages of eyes within ± 1.00 D of the PE, higher than the Kane and Pearl-DGS formulas (all P < 0.05). In the external test dataset, the Zhu-Lu formula also showed the highest percentages of eyes within ± 0.50 D of the PE (72.85%), followed by BUII (70.86%), EVO 2.0 (69.54%), Pearl-DGS (65.56%), RBF 3.0 (65.56%) and Kane (63.58%). All formulas predicted over 90% of eyes with PE within ± 1.00 D. Figure 3 shows cumulative distribution function curves of six formulas in both test datasets. In the internal test dataset, cumulative distribution function curves show that the distribution patterns of the absolute errors were different among formulas and the Zhu-Lu formula performed better than the other formulas (log-rank test, all P < 0.05) except for the RBF 3.0 formula (P = 0.058). In the external test data, the cumulative distribution function curve of the Zhu-Lu formula was comparable to the BUII, EVO 2.0 and RBF 3.0 formulas (logrank test, P = 0.219, 0.548 and 0.112, respectively), while significantly better than the Kane and Pearl-DGS formulas (both P < 0.05).

Fig. 2
figure 2

Percentages of eyes within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D of the prediction errors of each formula in the internal (a) and external (b) test datasets. BUII, Barrett Universal II; EVO, Emmetropia Verifying Optical; RBF, Radial Basis Function; D, diopter

Fig. 3
figure 3

Cumulative distribution function curves of absolute errors of each formula in highly myopic eyes in the internal (a) and external (b) test datasets. BUII, Barrett Universal II; EVO, Emmetropia Verifying Optical; RBF, Radial Basis Function; D, diopter

Subgroup analysis

The accuracies of the six formulas were further compared in different AL subgroups (Table 3). In the internal test dataset, the Zhu-Lu formula had significantly lower MedAEs than the BUII, EVO 2.0, Kane and Pearl-DGS formulas in all three AL subgroups (Friedman test with Bonferroni post hoc analysis, all P < 0.05). When compared to the RBF 3.0 formula, no significant difference was found. In the external test dataset, the Zhu-Lu formula had a significantly lower MedAE than the BUII, EVO 2.0 and Pearl-DGS formulas in the 26.00–28.00 mm AL subgroup (all P < 0.05), and statistically comparable with the Kane and RBF 3.0 formulas. In the 28.00–30.00 mm AL subgroup, there were no significant differences among formulas. In the AL ≥ 30.00 mm subgroup, the Zhu-Lu formula had a significantly lower MedAE than the Kane, RBF 3.0 and Pearl-DGS formulas (all P < 0.05).

Table 3 Comparison of the prediction errors using the BUII, EVO 2.0, Kane, Pearl-DGS, RBF 3.0 and Zhu-Lu formulas in different axial length subgroups of highly myopic eyes

Figure 4 demonstrates the effect of AL on PEs in both internal and external test datasets. The PEs of the Zhu-Lu formula were close to zero especially in extremely myopic eyes.

Fig. 4
figure 4

Prediction errors (mean ± standard deviation) versus axial length of each formula in highly myopic eyes in the internal (a) and external (b) test datasets. BUII, Barrett Universal II; EVO, Emmetropia Verifying Optical; RBF, Radial Basis Function; D, diopter

In addition, we further evaluated the performance of the Zhu-Lu formula in eyes with AL > 35.00 mm, which have been excluded from the internal and external test datasets due to the restrictions of RBF 3.0 and Kane formulas (Additional file 1: Table S1). It revealed that the MAE was 0.27 ± 0.25 D, and the MedAE achieved 0.23 D. Furthermore, 50.00%, 83.33%, 83.33% and 100.00% of them were within ± 0.25 D, ± 0.50 D, ± 0.75 D and ± 1.00 D of the PE, respectively.

Discussion

Current IOL power calculation formulas are not accurate enough for highly myopic eyes, especially in light of the increasing demand for multifocal IOL implantations [20, 21]. The newer generation of AI-based formulas, though achieving improved accuracies, still have some limitations when applied to highly myopic eyes [2, 22]. In this study, using the XGBoost and SVR machine learning models, we developed the novel Zhu-Lu formula, which demonstrated significantly improved accuracy compared to other AI-based formulas in highly myopic eyes.

The dataset for developing the Zhu-Lu formula is derived from the largest cohort (1462 eyes in the training dataset with AL ranging from 26.01 to 37.45 mm) of highly myopic cataract patients. For a machine learning based formula, plenty and credible training data are crucial to its accuracy and stability. Furthermore, the XGBoost and SVR algorithms are both highly accurate in data prediction and have helped with numerous situations in ophthalmology, such as diabetic retinopathy diagnosis, implantable collamer lens size selection, and post-cataract-surgery focus depth prediction [23,24,25]. Using the XGBoost, our group has previously developed an enhanced calculator for the BUII formula, which demonstrated improved prediction accuracy in highly myopic eyes [26, 27]. Yet this enhanced calculator might be influenced by the internal optimizations of the BUII formula itself, which is still unpublished to the public. Conversely, the current Zhu-Lu formula is based on theoretical formulas of SRK/T and Haigis and other feature transformations carried out inside the model, which can be used independently in clinical practice. Also, except for the XGBoost, the Zhu-Lu formula also adopted the SVR model [28], which may explain the improved performance compared to formulas using single algorithms such as the RBF 3.0. Notably, in this study, an assembled model using both algorithms and weighted average strategy of four sub-models was constructed, which could further enhance the robustness of Zhu-Lu formula.

A number of AI-based IOL calculation formulas have been developed in recent years. The BUII formula, an updated version of BU formula, was introduced in 2010 by Graham D Barrett and showed promising results in myopic eyes [10, 29, 30]. The EVO 2.0 formula generates an emmetropia factor for each eye and its 2.0 version is considered to have better prediction in long eyes [31,32,33]. The Kane formula was developed on the basis of both regression and AI elements and yielded decent outcomes in previous studies [33,34,35]. The Pearl-DGS formula, published in 2019, was an AI-based formula developed utilizing the support vector machine and multilayer neural networks and showed promising accuracy according to a recent study [36]. The RBF 3.0 formula was a data-driven IOL power calculator that had been continuously expanding its database. The 3.0 version was recently released, with reported better performance than the 2.0 version [7].

When applied to highly myopic eyes, the reported MedAEs of these formulas ranged from 0.22 to 0.33 D [22, 31, 34, 35, 37, 38]. In this study, we found that the Zhu-Lu formula outperformed the BUII, EVO 2.0, Kane and Pearl-DGS formulas in the internal test dataset. In the external test dataset, the Zhu-Lu formula had a MedAE that was significantly lower than the Pearl-DGS and RBF 3.0 formulas. Notably, the Zhu-Lu formula had a significantly lower MedAE than the BUII and EVO 2.0 formulas in the 26.00 to 28.00 mm subgroup. However, in the ≥ 30.00 mm subgroup, the Zhu-Lu formula performed similar to the BUII and EVO 2.0 formulas but outperformed the Kane and RBF 3.0 formulas. This phenomenon highlights the advantage of prediction stability of the Zhu-Lu formula in different AL ranges. Furthermore, the PEs of the Zhu-Lu formula were around zero and remained stable as AL elongates (Fig. 4).

The other noteworthy point of the Zhu-Lu formula is the improved percentages of eyes within ± 0.25 D and ± 0.50 D of the PE among highly myopic eyes, as compared to other formulas. For multifocal IOL implantations, pursuing higher percentage of eyes within ± 0.25 D or ± 0.50 D is important for satisfied postoperative distant and near vision [39]. Therefore, highly myopic eyes requiring multifocal IOL implantations may benefit a lot from the novel Zhu-Lu formula with better predictability and postoperative refractive outcomes.

Additionally, the performance of the Zhu-Lu formula in eyes with AL > 35 mm also remained stably promising. As no restrictions for target refraction or AL input limitations were set for the Zhu-Lu formula, the Zhu-Lu formula can apply to a wider range of highly myopic patients, especially those seeking better near visions. Overall, we suggest that the Zhu-Lu formula be used in highly or especially extremely myopic eyes.

Conclusions

In conclusion, we developed a novel Zhu-Lu formula exclusively for IOL power calculation and refractive prediction in highly myopic eyes. The model was derived from an extensive database, incorporated various biometric features, and took advantage of the XGBoost and the SVR machine learning algorithms. In both internal and external test datasets, the Zhu-Lu formula presented more promising outcomes in highly myopic eyes over the other AI-based formulas.

Availability of data and materials

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Abbreviations

ACD:

Anterior chamber depth

AI:

Artificial intelligence

AL:

Axial length

BCVA:

Best-corrected distance visual acuity

BUII:

Barrett Universal II

CD:

Horizontal corneal diameter

D:

Diopter

EVO:

Emmetropia verifying optical

IOL:

Intraocular lens

K:

Keratometry

LT:

Lens thickness

MAE:

Mean absolute error

MedAE:

Median absolute error

PE:

Prediction error

RBF:

Radial Basis Function

SD:

Standard deviation

SE:

Spherical equivalent

SVR:

Support vector regression

XGBoost:

EXtreme Gradient Boosting

References

  1. Melles RB, Holladay JT, Chang WJ. Accuracy of intraocular lens calculation formulas. Ophthalmology. 2018;125(2):169–78.

    Article  PubMed  Google Scholar 

  2. Carmona-González D, Castillo-Gómez A, Palomino-Bautista C, Romero-Domínguez M, Gutiérrez-Moreno MÁ. Comparison of the accuracy of 11 intraocular lens power calculation formulas. Eur J Ophthalmol. 2021;31(5):2370–6.

    Article  PubMed  Google Scholar 

  3. Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL. Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg. 2011;37(1):63–71.

    Article  PubMed  Google Scholar 

  4. Savini G, Hoffer KJ, Balducci N, Barboni P, Schiano-Lomoriello D. Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer. J Cataract Refract Surg. 2020;46(1):27–33.

    PubMed  Google Scholar 

  5. Olsen T. Intraocular lens power calculation errors in long eyes. J Cataract Refract Surg. 2012;38(4):733–4.

    Article  PubMed  Google Scholar 

  6. Khatib ZI, Haldipurkar SS, Shetty V, Dahake H, Nagvekar P, Kashelkar P. Comparison of three newer generation freely available intraocular lens power calculation formulae across all axial lengths. Indian J Ophthalmol. 2021;69(3):580–4.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Tsessler M, Cohen S, Wang L, Koch DD, Zadok D, Abulafia A. Evaluating the prediction accuracy of the Hill-RBF 3.0 formula using a heteroscedastic statistical method. J Cataract Refract Surg. 2022;48(1):37–43.

    Article  PubMed  Google Scholar 

  8. Ladas JG, Siddiqui AA, Devgan U, Jun AS. A 3-D “Super Surface” combining modern intraocular lens formulas to generate a “Super Formula” and maximize accuracy. JAMA Ophthalmol. 2015;133(12):1431–6.

    Article  PubMed  Google Scholar 

  9. Sramka M, Slovak M, Tuckova J, Stodulka P. Improving clinical refractive results of cataract surgery by machine learning. Peer J. 2019;7:e7202.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Barrett G. An improved universal theoretical formula for intraocular-lens power prediction. J Cataract Refract Surg. 1993;19(6):713–20.

    Article  CAS  PubMed  Google Scholar 

  11. Kane JX, Van Heerden A, Atik A, Petsoglou C. Intraocular lens power formula accuracy: comparison of 7 formulas. J Cataract Refract Surg. 2016;42(10):1490–500.

    Article  PubMed  Google Scholar 

  12. Holden BA, Fricke TR, Wilson DA, Jong M, Naidoo KS, Sankaridurg P, et al. Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050. Ophthalmology. 2016;123(5):1036–42.

    Article  PubMed  Google Scholar 

  13. Kane JX, Van Heerden A, Atik A, Petsoglou C. Accuracy of 3 new methods for intraocular lens power selection. J Cataract Refract Surg. 2017;43(3):333–9.

    Article  PubMed  Google Scholar 

  14. Wan KH, Lam TCH, Yu MCY, Chan TCY. Accuracy and precision of intraocular lens calculations using the new Hill-RBF version 2.0 in eyes with high axial myopia. Am J Ophthalmol. 2019;205:66–73.

    Article  PubMed  Google Scholar 

  15. Tianqi C, Carlos G. XGBoost. In: Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining. USA: San Francisco California; 2016. p.785–794

  16. Smola AJ, Scholkopf B. A tutorial on support vector regression. Stat Comput. 2004;14:199–222. https://doi.org/10.1023/B:STCO.0000035301.49549.88.

    Article  Google Scholar 

  17. Hoffer KJ, Savini G. Update on intraocular lens power calculation study protocols: the better way to design and report clinical trials. Ophthalmology. 2021;128(11):e115–20.

    Article  PubMed  Google Scholar 

  18. Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000;238(9):765–73.

    Article  CAS  PubMed  Google Scholar 

  19. Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg. 1990;16(3):333–40.

    Article  CAS  PubMed  Google Scholar 

  20. Geggel HS. Comparison of formulas and methods for high myopia patients requiring intraocular lens powers less than six diopters. Int Ophthalmol. 2018;38(4):1497–504.

    Article  PubMed  Google Scholar 

  21. Zhao J, Liu LP, Cheng HH, Li JB, Han XT, Liu Y, et al. Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens. Int J Ophthalmol. 2020;13(9):1378–84.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Ji J, Liu Y, Zhang J, Wu X, Shao W, Ma B, et al. Comparison of six methods for the intraocular lens power calculation in high myopic eyes. Eur J Ophthalmol. 2021;31(1):96–102.

    Article  PubMed  Google Scholar 

  23. Li W, Song Y, Chen K, Ying J, Zheng Z, Qiao S, et al. Predictive model and risk analysis for diabetic retinopathy using machine learning: a retrospective cohort study in China. BMJ Open. 2021;11(11):e050989.

    Article  PubMed  PubMed Central  Google Scholar 

  24. Shen Y, Wang L, Jian W, Shang J, Wang X, Ju L, et al. Big-data and artificial-intelligence-assisted vault prediction and EVO-ICL size selection for myopia correction. Br J Ophthalmol. 2023;107(2):201–6.

    Article  PubMed  Google Scholar 

  25. Liu Y, Wei D, Bai T, Luo J, Wood J, Vashisht A, et al. Using machine learning to predict post-operative depth of focus after cataract surgery with implantation of Tecnis Symfony. Eur J Ophthalmol. 2021;31(6):2938–46.

    Article  PubMed  Google Scholar 

  26. Wei L, Song Y, He W, Chen X, Ma B, Lu Y, et al. Accuracy improvement of IOL power prediction for highly myopic eyes with an XGBoost machine learning-based calculator. Front Med. 2020;7:592663.

    Article  Google Scholar 

  27. Wei L, Cheng K, He W, Zhu X, Lu Y. Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes. Eye Vis (Lond). 2022;9(1):21.

    Article  PubMed  Google Scholar 

  28. Brereton RG, Lloyd GR. Support vector machines for classification and regression. Analyst. 2010;135(2):230–67.

    Article  CAS  PubMed  Google Scholar 

  29. Hoffer KJ, Savini G. IOL power calculation in short and long eyes. Asia Pac J Ophthalmol (Phila). 2017;6(4):330–1.

    PubMed  Google Scholar 

  30. Liu J, Wang L, Chai F, Han Y, Qian S, Koch DD, et al. Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia. J Cataract Refract Surg. 2019;45(6):725–31.

    Article  PubMed  Google Scholar 

  31. Cheng H, Kane JX, Liu L, Li J, Cheng B, Wu M. Refractive predictability using the IOLMaster 700 and artificial intelligence-based IOL power formulas compared to standard formulas. J Refract Surg. 2020;36(7):466–72.

    Article  PubMed  Google Scholar 

  32. Hipólito-Fernandes D, Luís ME, Serras-Pereira R, Gil P, Maduro V, Feijao J, et al. Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison. Br J Ophthalmol. 2022;106(3):349–55.

    Article  PubMed  Google Scholar 

  33. Savini G, Di Maita M, Hoffer KJ, Næser K, Schiano-Lomoriello D, Vagge A, et al. Comparison of 13 formulas for IOL power calculation with measurements from partial coherence interferometry. Br J Ophthalmol. 2021;105(4):484–9.

    Article  PubMed  Google Scholar 

  34. Darcy K, Gunn D, Tavassoli S, Sparrow J, Kane JX. Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10930 eyes from the UK National Health Service. J Cataract Refract Surg. 2020;46(1):2–7.

    PubMed  Google Scholar 

  35. Lin L, Xu M, Mo E, Huang S, Qi X, Gu S, et al. Accuracy of newer generation IOL power calculation formulas in eyes with high axial myopia. J Refract Surg. 2021;37(11):754–8.

    Article  PubMed  Google Scholar 

  36. Shammas HJ, Taroni L, Pellegrini M, Shammas MC, Jivrajka RV. Accuracy of newer intraocular lens power formulas in short and long eyes using sum-of-segments biometry. J Cataract Refract Surg. 2022;48(10):1113–20.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Bernardes J, Raimundo M, Lobo C, Murta JN. A comparison of intraocular lens power calculation formulas in high myopia. J Refract Surg. 2021;37(3):207–11.

    Article  PubMed  Google Scholar 

  38. Connell BJ, Kane JX. Comparison of the Kane formula with existing formulas for intraocular lens power selection. BMJ Open Ophthalmol. 2019;4(1):e000251.

    Article  PubMed  PubMed Central  Google Scholar 

  39. Kim EJ, Sajjad A, Montes de Oca I, Koch DD, Wang L, Weikert MP, et al. Refractive outcomes after multifocal intraocular lens exchange. J Cataract Refract Surg. 2017;43(6):761–6.

    Article  PubMed  Google Scholar 

Additional sources

  1. Barrett Universal II Formula. Available from: http://calc.apacrs.org/barrett_universal2105/. Accessed 22 Jan 2023.

  2. Emmetropia Verifying Optical Formula. Available from: http://www.evoiolcalculator.com/. Accessed 22 Jan 2023.

  3. Kane Formula. Available from: http://www.iolformula.com/. Accessed 22 Jan 2023.

  4. Pearl-DGS Formula. Available from: https://news.iolsolver.com/. Accessed 22 Jan 2023.

  5. RBF 3.0 Formula. Available from: https://rbfcalculator.com/online/index.html/. Accessed 22 Jan 2023.

  6. Zhu-Lu Formula. Available from: https://HM-ZLF.com/. Accessed 22 Jan 2023.

  7. IOL Con website. Available from: https://www.iolcon.org/. Accessed 22 Jan 2023.

Download references

Acknowledgements

Not applicable.

Funding

This study was supported by the National Natural Science Foundation of China (Grant Nos. 82271069, 82122017, 81870642, 81970780, 81470613 and 81670835), Science and Technology Innovation Action Plan of Shanghai Science and Technology Commission (Grant Nos. 19441900700 and 21S31904900), Clinical Research Plan of Shanghai Shenkang Hospital Development Center (Grant Nos. SHDC12020111, SHDC12019X08 and SHDC2020CR4078), Double-E Plan of Eye & ENT Hospital (Grant No. SYA202006), Shanghai Municipal Key Clinical Specialty Program (Grant No. shslczdzk01901), and the Fudan University Outstanding 2025 Program.

Author information

Authors and Affiliations

Authors

Contributions

XZ and YL designed the study and obtained the fundings. DG, WH, LW, YS, XC, JH collected, analyzed and interpreted the patient data. DG, WH, LW and YS are major contributors in writing the manuscript. JQ, YY, XZ revised the manuscript. All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Yi Lu or Xiangjia Zhu.

Ethics declarations

Ethics approval and consent to participate

This retrospective study was approved by the Institutional Review Board of the Eye & Ear, Nose, and Throat Hospital of Fudan University, Shanghai, China (ID: 2020005). All procedures adhered to the tenets of the Declaration of Helsinki. All participants provided written informed consent before cataract surgery for the use of their clinical data.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Supplementary Information

Additional file 1: Table S1.

Performance of the Zhu-Lu formula in eyes with AL > 35 mm.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Guo, D., He, W., Wei, L. et al. The Zhu-Lu formula: a machine learning-based intraocular lens power calculation formula for highly myopic eyes. Eye and Vis 10, 26 (2023). https://doi.org/10.1186/s40662-023-00342-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40662-023-00342-5

Keywords