Impact of ablation ratio on 5-year postoperative posterior corneal stability after refractive surgery: SMILE and FS-LASIK

Abstract

Background

To investigate the impact of the ablation ratio on 5-year postoperative posterior corneal stability in myopic eyes after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) surgery.

Methods

A prospective, nonrandomized, cohort study: 80 eyes of 43 patients underwent SMILE surgery and 63 eyes of 32 patients underwent FS-LASIK surgery at the EYE & ENT Hospital, Fudan University. Ablation ratio was defined as lenticule thickness (SMILE cases) or ablation depth (FS-LASIK cases) divided by central corneal thickness (CCT). Posterior corneal elevation changes were recorded as posterior central elevation (PCE), posterior corneal surface at thinnest point (PTE) and posterior corneal mean elevation (PME). Patients were followed up at 6-month and 5-year interval to investigate the impact of the ablation ratio on posterior corneal elevation after SMILE and FS-LASIK surgery.

Results

PCE dropped at the 6-month follow-up for both SMILE (decreased by −1.11 ± 2.93 μm, P < 0.05) and FS-LASIK groups (decreased by −0.46 ± 3.72 μm, P < 0.05). PTE also dropped in SMILE (reduced by −2.04 ± 3.02 μm, P < 0.05) and FS-LASIK group (reduced by −1.28 ± 4.21 μm, P < 0.05) at the 6-month follow-up. Stable PCE (elevation change: SMILE −0.28 ± 4.03 μm; FS-LASIK 0.79 ± 4.13 μm, P > 0.05) and PTE (elevation change: SMILE −0.08 ± 4.28 μm; FS-LASIK 1.42 ± 3.85 μm, P > 0.05) for both groups were recorded at the 5-year follow-up compared to the 6-month visit. Ablation ratio was strongly correlated with 5-year postoperative PCE (β = 2.68 ± 1.05, P < 0.01) and PTE (β = 2.35 ± 1.17, P < 0.05). Cut-off value for 5-year postoperative raised PCE and PTE was 27.3 and 27.1%, respectively.

Conclusions

Ablation ratio was strongly correlated with postoperative posterior corneal elevation in a 5-year follow-up in both SMILE and FS-LASIK groups. PCE and PTE underwent slight backward displacement 6-month postoperatively and remain stable at the 5-year follow-up. Threshold of the ablation ratio for resisting forward displacement of posterior corneal surface was 27.3 and 27.1% for SMILE and FS-LASIK groups, respectively.

Background

Small incision lenticule extraction (SMILE) surgery is a flap-free, small-incision refractive operation introduced in 2011 by Sekundo and Shah in correcting myopia with stable visual outcomes in both the short- and long-term and is believed with better post-operative corneal stability compared with femtosecond laser-assisted in situ keratomileusis (FS-LASIK) [1,2,3,4]. To date, about 3 million SMILE surgeries have been carried out worldwide in more than 70 countries [5]. Iatrogenic corneal ectasia is one of the most feared complications following nearly all keratorefractive surgeries in that it disturbs the integrity of the cornea. Keratoectasia following SMILE surgeries is rare. Only 7 eyes of four patients have been reported in literature [6].

Posterior corneal elevation is neither affected by surgery incision or flap creation nor easily influenced by tear film, and thus was reported as an early indicator for evaluating postoperative corneal stability with good repeatability and reliability [7,8,9]. Previous studies reported that risk factors of ectasia post LASIK and photorefractive keratectomy (PRK) surgeries include residual bed thickness (RBT), preoperative corneal thickness, abnormal corneal topography, age and high myopia state [10]. However, risk factors of forward posterior corneal displacement post SMILE and FS-LASIK surgery in the long term remain unknown.

This study aims to record a 5-year follow-up of posterior corneal elevation change and reveal the correlation between an individualized metric “ablation ratio” and postoperative posterior corneal stability.

Methods

Study design and participants

Eighty eyes of 43 patients undergoing SMILE surgery and 63 eyes of 32 patients undergoing FS-LASIK surgery at Eye and ENT Hospital of Fudan University were enrolled in this prospective, nonrandomized, cohort study from December 2011 to March 2012 and from January to February 2013. The eligibility criteria for both surgical groups were: age > 18 years, corrected distance visual acuity (CDVA) ≥ 20/20, refractive error remained stable in recent 2 years without other ocular pathologies, calculated RBT without epithelium > 280 μm. Patients were routinely examined and met the criteria for either SMILE or FS-LASIK. Patients with systemic or other ocular diseases, history of ocular surgeries or trauma, pregnant or breast-feeding state were excluded from this study. The exclusion criteria for both surgical groups were the same. This study was approved by Ethical Committee of Eye and ENT Hospital of Fudan University Review Board (KJ2010–18) and the study was conducted in accordance with the tenets of the Declaration of Helsinki. Each patient chose one of the two procedures after fully understanding the risks and benefits of both surgeries and provided written informed consent. Detailed patient characteristics were summarized in Table 1.

Table 1 Patient characteristics

Data collection and analysis

Elevation of posterior corneal surface, corneal thickness and topography were measured by Pentacam HR (Oculus GmbH, Wetzlar, Germany). One picture of each enrolled eye was taken in the preoperative examination and each follow-up. An image with “OK” statements under inspection window and central 9 mm corneal area covered qualified for further analysis. Posterior corneal elevation changes were recorded in three parameters: posterior central elevation (PCE), posterior corneal surface at thinnest point (PTE) and posterior corneal mean elevation (PME). PME was the average height of 8 points taken from a 4 mm diameter concentric circle (i.e., 2 mm from the center at 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315° semi-meridians). Reference best fit sphere (BFS) was determined by the central 8 mm area of the preoperative cornea to ensure that the BFS of all postoperative maps were comparable with preoperative data. Ablation ratio was calculated as lenticule thickness/central corneal thickness (CCT) in SMILE group and ablation depth/CCT in FS-LASIK group. Lenticule thickness and ablation depth were extracted from each surgical laser system.

Surgical procedures

SMILE surgery was performed by VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Jena, Germany) with laser settings of 500 kHz repetition, 130 nJ pulse energy. A spot distance of 2.5 μm was used for the lenticule cut and cap cut and 2.0 μm for the lenticule side-cut and cap side-cut. An S-size contact glass was applied. The attempted treatment center was the corneal vertex. The corneal cap thickness was 100 to 110 μm. Target lenticule diameter (optical zone) was set to 6.0–6.8 mm depending on preoperative corneal thickness and refractive error to be corrected. Tissue arcade diameter was set 1 mm larger than the diameter of the lenticule. The lenticule side cut and opening incision side cut were fixed at 90 degrees with a circumferential width of 2.0 to 4.5 mm.

High-precision flap in FS-LASIK surgery was created by the same VisuMax femtosecond laser system with a pulse energy of 185 nJ. Stromal ablation was performed by MEL 80 excimer laser (Carl Zeiss Meditec, Oberkochen, Germany) with laser settings of 250 Hz repetition and 1 mJ pulse energy. The intended flap thickness was 100 μm. The hinges were set at a superior orientation with a hinge length of 4.0 mm. Patients wore bandage soft contact lenses (ACUVE OASYS, Inc., FL, USA) for 1 day after surgery. S cone was used in both procedures. All surgeries were conducted by an experienced refractive surgeon (ZXT).

Postoperative topical medication regimens were identical for both groups consisting of an ophthalmic solution of levofloxacin (Cravit®; Santen, Osaka, Japan) four times per day for 7 days, a 0.1% fluorometholone solution (Flumetholon®; Santen, Osaka, Japan) from 8 times to 1 time per day over a course of 24 days and a tear supplement 4 times per day for 1 month.

Follow-up and statistical analysis

Patients were followed up at 6-month and 5-year interval with postoperative visual outcomes and posterior corneal elevation data collected for evaluation. Categorical variables were summarized by frequencies and percentages and tested by Chi-squared test. Continuous variables with a normal distribution were summarized by mean ± standard deviation and tested by t-test. Continuous variables with a nonnormal distribution were summarized by median and interquartile range, tested by Wilcoxon rank-sum test. A sample size of 51 eyes per group was calculated to detect a 1.4 μm difference of posterior corneal elevation between two surgical groups with an intended power of 90% and a significance level of 5% [11, 12]. Mixed effect model was applied to analyze postoperative posterior corneal elevation change with adjustment for preoperative spherical equivalent. Univariable and multivariable analysis were performed to determine independent relationship between baseline parameters and potential risk factors of postoperative posterior corneal elevation measurements. The analysis was performed with generalized estimating equations (GEE). To avoid the impact of the fellow eye in this study, we applied GEE with the fellow eye as covariate, namely eyes (two per individual) were clustered at subject level. Correlation coefficient β indicates the magnitude and direction of posterior corneal elevation change with per unit increase of the risk factor parameter. The cut-off value of ablation ratio was determined by the point of maximum Youden’s index (J). J can be formally defined as J = maxc {Se (c) + Sp (c) − 1}, in which Se (c) and Sp (c) were sensitivity and specificity at a certain point c [13]. Statistical analyses were performed with SPSS (version 22.0; IBM Corp., Armonk, NY). P < 0.05 was considered statistically significant.

Results

Visual outcomes

Forty-three patients (80 eyes) undergoing SMILE surgery and 32 patients (63 eyes) undergoing FS-LASIK surgery were included in this study. Thirteen patients (23 eyes) were lost in the 6-month follow-up but reengaged in the 5-year follow-up. Nine (12%) patients in total (17 eyes, SMILE group, 11 eyes, FS-LASIK group: 6 eyes) were lost in the 5-year follow-up because they were untraceable via phone numbers. No patients encountered post-operative keratectasia, dry eye, infectious keratitis, and other complications in this study. In the five-year follow-up of both groups, no eyes lost 2 lines or more of CDVA postoperatively. 90% (62/69) eyes in the SMILE group and 79% (45/57) eyes in the FS-LASIK group achieved uncorrected distance visual acuity (UDVA) of 20/20 or better. Safety and efficacy indices were 1.18 and 1.14 for the SMILE group, 1.21 and 1.06 for the FS-LASIK group. In the 5-year follow-up, spherical equivalent of 90% (62/69) eyes of the SMILE group were within 0.5 D of target correction and 99% (68/69) eyes within 1.0 D of target correction. 96% (66/69) eyes in the SMILE group had astigmatism ≤ 0.5 D. Spherical equivalent of 70% (39/57) eyes in FS-LASIK group were within 0.5 D of target correction and 88% (50/57) eyes within 1.0 D of target correction. 86% (49/57) eyes of FS-LASIK group remained astigmatism ≤ 0.5 D. Detailed visual outcomes were reported in Fig. 1.

Fig. 1
figure 1

Visual outcomes of SMILE and FS-LASIK groups. a. Five-year postoperative cumulative uncorrected distance visual acuity; b. Five-year postoperative corrected distance visual acuity; c. Attempted versus achieved spherical equivalent refraction after SMILE at five-year follow-up; d. Attempted versus achieved spherical equivalent refraction after FS-LASIK at five-year follow-up; e. Five-year postoperative spherical equivalent refraction change; f. Five-year postoperative refractive astigmatism; g. Time-dependent changes of spherical equivalent. SMILE = small incision lenticule extraction; FS-LASIK = femtosecond laser-assisted in situ keratomileusis; CDVA = corrected distance visual acuity; logMAR = logarithm of the minimal angle of resolution

Posterior corneal elevation changes

No statistically significant differences were recorded for PCE, PTE and PME between the SMILE and FS-LASIK groups at baseline (P > 0.05).

PCE underwent a backward displacement in the 6-month follow-up for both SMILE (dropped by −1.11 ± 2.93 μm, P < 0.05) and FS-LASIK groups (dropped by −0.46 ± 3.72 μm, P < 0.05) compared with preoperative baseline. PCE in the 6-month follow-up averaged 0.26 ± 4.09 μm for the SMILE group, and 1.53 ± 4.03 μm for the FS-LASIK group. PCE then remained stable in the 5-year follow-up (elevation change: −0.28 ± 4.03 μm, P > 0.05) in comparison with 6-month follow-up (Fig. 2a). The five-year postoperative PCE was 0.30 ± 5.25 μm for the SMILE group and 1.63 ± 5.83 μm for the FS-LASIK group.

Fig. 2
figure 2

Posterior corneal elevation changes at the 6-month and 5-year follow-up. a. PCE change; b. PTE change; c. PME change. PCE = posterior central elevation; PTE = posterior corneal surface at thinnest point; PME = posterior corneal mean elevation; NS = not significant. P values were adjusted for preoperative spherical equivalent in mixed effect model. P values less than 0.05 were considered statistically significant

Pattern of PTE fluctuation was comparable with PCE in chronological order. PTE also underwent a backward displacement in the 6-month follow-up for both SMILE (dropped by −2.04 ± 3.02 μm, P < 0.05) and FS-LASIK groups (dropped by −1.28 ± 4.21 μm, P < 0.05). Unchanged PTE in 5-year follow-up for SMILE (elevation change: −0.08 ± 4.28 μm, P > 0.05) and FS-LASIK (elevation change: −1.42 ± 3.85 μm, P > 0.05) groups were recorded compared to 6-month follow-up (Fig. 2b).

PME remained unaffected at 6 months (elevation change: SMILE 0.30 ± 1.54 μm, P > 0.05; LASIK 0.29 ± 1.42 μm, P > 0.05) and 5 year (elevation change: SMILE 0.32 ± 1.96 μm, P > 0.05; LASIK 0.68 ± 2.03 μm, P > 0.05) follow-up for both groups compared with preoperative data (Fig. 2c).

No differences of statistical significance were noted between SMILE and FS-LASIK groups in relation to PCE, PTE and PME during each follow-up while adjusting for preoperative SE (P > 0.05).

Associations between posterior corneal stability and ablation ratio

Ablation ratio was strongly correlated with 5-year postoperative PCE (β = 2.68 ± 1.05, P < 0.01) and PTE (β = 2.35 ± 1.17, P < 0.05) as an independent risk factor while adjusting for age, sex and surgical procedures. Cut-off point for 5-year postoperative raised PCE and PTE was 27.3 and 27.1%, respectively, as determined by maximum Youden’s index. Males (P < 0.05) and younger age (P < 0.05) were associated with backward displacement of PCE and PTE at the 6-month follow-up. Univariate and multivariate analysis of parameters associated with posterior corneal elevation in each follow-up are summarized in Table 2.

Table 2 Parameters associated with posterior corneal elevation at 6-month and 5-year follow-up

Discussion

Pentacam, by manipulating a rotating Scheimpflug camera to directly construct an elevation map without causing false positive forward elevation induced by mathematical reconstruction, has now replaced Orbscan II as a standard measurement for corneal topography before and after keratorefractive surgeries [14,15,16,17].

With posterior corneal forward displacement proved to be an important warning sign of postoperative corneal instability, posterior corneal elevation has long been adopted in evaluating corneal displacement after nearly all keratorefractive surgeries including PRK [18], laser assisted subepithelial keratomileusis (LASEK), sub-Bowman’s keratomileusis (SBK) [19], LASIK [20] and SMILE [21].

In this study, PCE change (6-month: −1.11 ± 2.93 μm, 5-year: −1.44 ± 3.93 μm) and PTE change (6-month: −2.04 ± 3.02 μm, 5-year: −2.41 ± 4.56 μm) of SMILE group were comparable to Zhao et al. (PCE, 6-month: 0.33 ± 3.94 μm, 3-year: −1.42 ± 3.48 μm; PTE, 6-month: 1.81 ± 4.08 μm, 3-year: 0.36 ± 4.13 μm) [8] and Zhou et al. (PCE, 6-month: −0.23 ± 2.43 μm, 2-year: −1.18 ± 3.06 μm; PTE, 6-month: −1.53 ± 3.56 μm, 2-year: −1.94 ± 3.21 μm) studies [12] with slightly more backward shift in all follow-up data.

A slight backward displacement of PCE and PTE with statistical significance was witnessed at the postoperative 6-month interval in both SMILE and FS-LASIK groups. This phenomenon was observed by Zhou et al. in high myopia patients in their 6-month follow-up after SMILE and FS-LASIK surgeries as well [12]. Yu et al. reported a backward shift of PCE in both SMILE and LASEK group in both 3-month and 3-year follow-ups without recording PTE data [21]. The same short-term backward shift was also noticed in PCE of rabbit eyes post-SMILE surgery [22]. The backward shift of PCE and PTE observed in this study may be explained by wound-remodeling in the early stage [23]. Postoperative thickening of the unablated peripheral stroma could cause flattening of posterior cornea surface [24] and may also contribute to the backward shift of PCE and PTE. Though there were some earlier studies reporting an obvious forward shift after LASIK or LASEK surgeries, most of them described a false positive forward elevation exacerbated by Orbscan [25, 26].

With respect to PME, this study selected posterior elevation of a 4 mm diameter concentric circle averaged for PME calculation whilst some studies picked central 2 or 6 [23, 27] or even 7 mm [28] area for analysis. The lack of protocol in assessing posterior corneal surface has made it difficult to make comparisons between different studies. PME changes of central 4 mm area were of no statistical importance in each follow-up in this study. It could possibly be due to the asphericity of the posterior corneal surface. As discovered by Zhou et al., PME of the temporal area underwent a more obvious backward displacement than nasal, superior and inferior areas [12]. Changes in PME remain unnoticed in our study when 8 points of the concentric 4 mm zone were simply averaged.

In this study, no difference of postoperative posterior corneal elevation change was noted between SMILE and FS-LASIK groups in each follow-up visit after adjusting for preoperative SE. With no adjustment for preoperative data, slightly greater PCE and PME changes could be seen in FS-LASIK group than SMILE group in previous studies [12, 29].

We applied ablation ratio (SMILE: lenticule thickness/CCT; FS-LASIK: ablation depth/CCT), namely percentage of ablated corneal tissue, in this study to evaluate risk factors of postoperative posterior corneal forward elevation instead of adopting “one-size-fits-all” metrics like RBT, ablation depth, lenticule thickness. Ablation ratio was a relatively individualized metric to describe postoperative corneal alteration. Some studies adopted other customized parameters like percent tissue altered (PTA) [30, 31], modified PTA [6] or corneal ratio (corneal depth/pachymetry) [32] to analyze the postoperative biomechanical destabilization. It is worth noting that that the ablation ratio, like any other customized metric, could hardly be a perfect parameter in estimating corneal topographic features based on the fact that the cohesive tensile strength of human cornea stroma is not evenly distributed, but progressively weakened from the anterior to the posterior surface [33].

The ablation ratio was strongly correlated with 5-year postoperative PCE (β = 2.68 ± 1.05, P < 0.01) and PTE (β = 2.35 ± 1.17, P < 0.05). However, the correlation was not noted in the 6-month follow-up. The missed correlation corroborated with another short-term observation study [34]. Brenner et al. found that in post-LASIK ectasia cases, the ablation ratio had a strong association with the severity of the ectasia and ablation ratio more than 20% would particularly increase the risk for post-LASIK ectasia CDVA loss [32]. No patients in the SMILE or FS-LASIK groups in this study suffered from iatrogenic keratectasia at the 5-year follow-up. We determined in this study that threshold of ablation ratio to resist a forward displacement of posterior corneal surface was 27.3 and 27.1% for the SMILE and FS-LASIK groups, respectively.

Limitations of this current study include firstly, the study did not adopt randomization after considering patients’ benefits since long-term effect of SMILE surgery remained unknown at the time of enrollment. Secondly, spherical refractive error, cylindrical refractive error and spherical equivalent of two groups were statistically different in this study due to the relative low number of patients and of the non-randomization, which limited the validity of the study. Thirdly, only two follow-up time points were picked in this study with the six-month and five-year follow-up representing a short and long-time observation, respectively. Lastly, this study failed to consider asphericity of the posterior corneal elevation by using BFS instead of best fit toric ellipsoid and simply averaging posterior elevation without differentiating between different hemispheres.

Conclusions

In summary, postoperative PCE and PTE of SMILE and FS-LASIK groups underwent slight backward displacement at 6 months but remained stable at 5 years follow-up. Ablation ratio was strongly correlated with postoperative posterior corneal elevation. The threshold of the ablation ratio for resisting forward displacement of posterior corneal surface was 27.3 and 27.1% for the SMILE and FS-LASIK groups, respectively.

Availability of data and materials

Available from the corresponding author upon reasonable request.

Abbreviations

SMILE:

Small incision lenticule extraction

FS-LASIK:

Femtosecond laser-assisted in situ keratomileusis

CCT:

Central corneal thickness

PCE:

Posterior central elevation

PTE:

Posterior corneal surface at thinnest point

PME:

Posterior corneal mean elevation

PRK:

Photorefractive keratectomy

CDVA:

Corrected distance visual acuity

RBT:

Residual bed thickness

logMAR:

Logarithm of the minimal angle of resolution

UDVA:

Uncorrected distance visual acuity

D:

Diopter

BFS:

Best fit sphere

GEE:

Generalized estimating equations

LASEK:

Laser assisted subepithelial keratomileusis

SBK:

Sub-Bowman’s keratomileusis

References

  1. Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol. 2011;95(3):335–9.

    Article  PubMed  Google Scholar 

  2. Shah R, Shah S, Sengupta S. Results of small incision lenticule extraction: all-in-one femtosecond laser refractive surgery. J Cataract Refract Surg. 2011;37(1):127–37.

    Article  PubMed  Google Scholar 

  3. Li M, Li M, Chen Y, Miao H, Yang D, Ni K, et al. Five-year results of small incision lenticule extraction (SMILE) and femtosecond laser LASIK (FS-LASIK) for myopia. Acta Ophthalmol. 2019;97(3):e373–80.

    Article  PubMed  Google Scholar 

  4. Wu W, Wang Y. Corneal higher-order aberrations of the anterior surface, posterior surface, and total cornea after SMILE, FS-LASIK, and FLEx surgeries. Eye Contact Lens. 2016;42(6):358–65.

    Article  PubMed  Google Scholar 

  5. Wang Y, Ma J. Future developments in SMILE: higher degree of myopia and hyperopia. Asia Pac J Ophthalmol (Phila). 2019;8(5):412–6.

    Article  CAS  Google Scholar 

  6. Moshirfar M, Albarracin JC, Desautels JD, Birdsong OC, Linn SH, Hoopes PC. Ectasia following small-incision lenticule extraction (SMILE): a review of the literature. Clin Ophthalmol. 2017;11:1683–8.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Kamiya K, Oshika T. Corneal forward shift after excimer laser keratorefractive surgery. Semin Ophthalmol. 2003;18(1):17–22.

    Article  PubMed  Google Scholar 

  8. Zhao Y, Jian W, Chen Y, Knorz MC, Zhou X. Three-year stability of posterior corneal elevation after small incision lenticule extraction (SMILE) for moderate and high myopia. J Refract Surg. 2017;33(2):84–8.

    Article  PubMed  Google Scholar 

  9. McAlinden C, Khadka J, Pesudovs K. A comprehensive evaluation of the precision (repeatability and reproducibility) of the oculus Pentacam HR. Invest Ophthalmol Vis Sci. 2011;52(10):7731–7.

    Article  PubMed  Google Scholar 

  10. Santhiago MR, Giacomin NT, Smadja D, Bechara SJ. Ectasia risk factors in refractive surgery. Clin Ophthalmol. 2016;10:713–20.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Friedman LM, Furberg CD, DeMets DL, Reboussin DM, Granger CB. Fundamentals of clinical trials. Springer; 2015.

  12. Zhou X, Shang J, Qin B, Zhao Y, Zhou X. Two-year observation of posterior corneal elevations after small incision lenticule extraction (SMILE) for myopia higher than −10 dioptres. Br J Ophthalmol. 2020;104(1):142–8.

    Article  PubMed  Google Scholar 

  13. Youden WJ. Index for rating diagnostic tests. Cancer. 1950;3(1):32–5.

    Article  CAS  PubMed  Google Scholar 

  14. Byun YS, Chung SH, Park YG, Joo CK. Posterior corneal curvature assessment after Epi-LASIK for myopia: comparison of Orbscan II and Pentacam imaging. Korean J Ophthalmol. 2012;26(1):6–9.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Grewal DS, Brar GS, Grewal SPS. Posterior corneal elevation after LASIK with three flap techniques as measured by Pentacam. J Refract Surg. 2011;27(4):261–8.

    Article  PubMed  Google Scholar 

  16. González-Pérez J, González-Méijome JM, Rodríguez Ares MT, Parafita MÁ. Central corneal thickness measured with three optical devices and ultrasound pachometry. Eye Contact Lens. 2011;37(2):66–70.

    Article  PubMed  Google Scholar 

  17. Chen D, Lam AKC. Reliability and repeatability of the Pentacam on corneal curvatures. Clin Exp Optom. 2009;92(2):110–8.

    Article  PubMed  Google Scholar 

  18. Nam SM, Im CY, Lee HK, Kim EK, Kim TI, Seo KY. Accuracy of RTVue optical coherence tomography, pentacam, and ultrasonic pachymetry for the measurement of central corneal thickness. Ophthalmology. 2010;117(11):2096–103.

    Article  PubMed  Google Scholar 

  19. Yan P, Du Z, Wu N, Zhang Y, Xu Y. Minor influence of sub-bowman keratomileusis on the posterior corneal surface at early stage. Curr Eye Res. 2013;38(8):871–9.

    Article  PubMed  Google Scholar 

  20. Queirós A, Villa-Collar C, Gutiérrezá ÁR, Jorge J, Ribeiro-Queirós MS, Peixoto-De-Matos SC, et al. Anterior and posterior corneal elevation after orthokeratology and standard and customized LASIK surgery. Eye Contact Lens. 2011;37(6):354–8.

  21. Yu M, Chen M, Dai J. Comparison of the posterior corneal elevation and biomechanics after SMILE and LASEK for myopia: a short- and long-term observation. Graefes Arch Clin Exp Ophthalmol. 2019;257(3):601–6.

  22. He M, Wang W, Ding H, Zhong X. Comparison of two cap thickness in small incision lenticule extraction: 100 μm versus 160 μm. PLoS One. 2016;11(9):e0163259.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Zhang L, Wang Y. The shape of posterior corneal surface in normal, post-LASIK, and post-epi-LASIK eyes. Invest Ophthalmol Vis Sci. 2010;51(7):3468–75.

    Article  PubMed  Google Scholar 

  24. Dupps WJ, Roberts C. Effect of acute biomechanical changes on corneal curvature after photokeratectomy. J Refract Surg. 2001;17(6):658–69.

    PubMed  Google Scholar 

  25. Martin R, Rachidi H. Stability of posterior corneal elevation one year after myopic laser in situ keratomileusis. Clin Exp Optom. 2012;95(2):177–86.

    Article  PubMed  Google Scholar 

  26. Kim H, Hyun JK, Joo CK. Comparison of forward shift of posterior corneal surface after operation between LASIK and LASEK. Ophthalmologica. 2005;220(1):37–42.

    Article  Google Scholar 

  27. Zhao Y, Li M, Zhao J, Knorz MC, Sun L, Tian M, et al. Posterior corneal elevation after small incision lenticule extraction for moderate and high myopia. PLoS One. 2016;11(2):e0148370.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Khairat YM, Mohamed YH, Moftah IA, Fouad NN. Evaluation of corneal changes after myopic LASIK using the Pentacam ®. Clin Ophthalmol. 2013;7:1771–6.

    PubMed  PubMed Central  Google Scholar 

  29. Wang B, Zhang Z, Naidu RK, Chu R, Dai J, Qu X, et al. Comparison of the change in posterior corneal elevation and corneal biomechanical parameters after small incision lenticule extraction and femtosecond laser-assisted LASIK for high myopia correction. Contact Lens Anterior Eye. 2016;39(3):191–6.

    Article  PubMed  Google Scholar 

  30. Santhiago MR, Smadja D, Gomes BF, Mello GR, Monteiro MLR, Wilson SE, et al. Association between the percent tissue altered and post-laser in situ keratomileusis ectasia in eyes with normal preoperative topography. Am J Ophthalmol. 2014;158(1):87–95.e1.

  31. Santhiago MR, Smajda D, Wilson SE, Randleman JB. Relative contribution of flap thickness and ablation depth to the percentage of tissue altered in ectasia after laser in situ keratomileusis. J Cataract Refract Surg. 2015;41(11):2493–500.

    Article  PubMed  Google Scholar 

  32. Brenner LF, Alió JL, Vega-Estrada A, Baviera J, Beltrán J, Cobo-Soriano R. Clinical grading of post-LASIK ectasia related to visual limitation and predictive factors for vision loss. J Cataract Refract Surg. 2012;38(10):1817–26.

    Article  PubMed  Google Scholar 

  33. Randleman JB, Dawson DG, Grossniklaus HE, McCarey BE, Edelhauser HE. Depth-dependent cohesive tensile strength in human donor corneas: implications for refractive surgery. J Refract Surg. 2008;24(1):S85–9.

    Article  PubMed  Google Scholar 

  34. Cagini C, Messina M, Lupidi M, Piccinelli F, Fiore T, Fruttini D, et al. Posterior corneal surface stability after femtosecond laser-assisted keratomileusis. J Ophthalmol. 2015;2015:184850.

    PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This study was supported by National Natural Science Foundation of China (Grant numbers 81500753; 81770955), Joint Research Project of New Frontier Technology in Municipal Hospitals (Grant number SHDC12018103), Project of Shanghai Science and Technology (Grant number 17411950200).

Author information

Authors and Affiliations

Authors

Contributions

ML: Conceptualization, data collection, manuscript drafting, critical revision, and statistical analysis. DY: Conceptualization, data collection, manuscript drafting, critical revision, and statistical analysis. YZ: Data collection and manuscript drafting. WY: Data collection and manuscript drafting. JS: Data collection and manuscript drafting. XZ: Data collection and manuscript drafting. YD: Data collection and manuscript drafting. XL: Conceptualization, critical revision of manuscript, funding, management, and supervision. XZ: Conceptualization, critical revision of manuscript, funding, management, and supervision. Both XL and XZ are corresponding authors. All authors approved the final submission of this manuscript.

Corresponding authors

Correspondence to Xue Lin or Xingtao Zhou.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the Ethical Committee of Fudan University Eye and ENT Hospital Review Board (Project-ID: KJ2010–08). Written informed consent was obtained from each patient.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Li, M., Yang, D., Zhao, Y. et al. Impact of ablation ratio on 5-year postoperative posterior corneal stability after refractive surgery: SMILE and FS-LASIK. Eye and Vis 7, 53 (2020). https://doi.org/10.1186/s40662-020-00218-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40662-020-00218-y

Keywords