Parameter | TE | PF MicroShunt | P* |
---|---|---|---|
Number of 5-FU injections | 82 | 186 |  < 0.01 |
Number of eyes receiving 5-FU injections (total/percentage) | 25 (24.04%) | 52 (62.65%) |  < 0.01 |
Number of needlings | 22 | 32 | 0.01 |
Number of eyes receiving needlings (total/percentage) | 19 (18.27%) | 28 (33.74%) | 0.02 |
AC reformation | 7 (6.73%) | 4 (4.82%) | 0.76 |
Wound suture/bleb leakage | 2 (1.92%) | 2 (2.41%) | 1.00 |
Laser suture lysis | 13 (12.50%) | 0 |  < 0.01 |
Releasable suture removal | 1 (0.96%) | 0 | 1.00 |
Revision surgery | 6 | 8 | 0.41 |
Cataract surgery (phacoemulsification) | 6 | 2 | 0.30 |
Secondary glaucoma surgery | 4 (1 × Baerveldt tube, 1 × Ahmed tube, 2 × Cyclophotocoagulation) | 4 (3xTE, 1 × Baerveldt tube) | 1.00 |
Mean number of appointments per case | 10.10 ± 3.60 | 9.40 ± 2.80 | 0.38 |