Skip to main content

Table 3 Refractive outcomes

From: Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: a comparison of three-piece and one-piece intrascleral fixation technique

Formula

 

Constant

APE (D)

MAE (D)

MedAE (D)

% within ±0.5D

% within ± 1.0 D

% within ± 2.0 D

SRK/T

Yamane

119.10

− 0.16 ± 0.56

0.52

0.47

54.0

87.5

100

Carlevale

118.92

− 0.10 ± 0.80

0.68

0.52

44.8

72.4

100

Holladay 1

Yamane

1.73

0.02 ± 0.56

0.45

0.38

62.5

91.7

100

Carlevale

1.75

− 0.04 ± 0.74

0.61

0.49

51.7

75.9

100

Hoffer Q

Yamane

5.34

0.13 ± 0.64

0.45

0.29

70.8

83.3

100

Carlevale

5.48

0.04 ± 0.75

0.62

0.60

44.8

75.9

100

  1. D = diopters; APE = arithmetic prediction error; MAE = mean absolute prediction error; MedAE = median absolute prediction error; % within = the percentage of eyes within a certain prediction error