Skip to main content

Table 2 Comparison of the classification performance on private anterior segment optical coherence tomography (AS-OCT) video datasets and image datasets

From: Dynamic analysis of iris changes and a deep learning system for automated angle-closure classification based on AS-OCT videos

 

AUC (95% CI)

Sensitivity

Specificity

Accuracy

Precision

Recall

F1 Score

Kappa

Casia dataset

 Images

0.766 (0.610–0.923)

0.790

0.750

0.771

0.771

0.771

0.771

0.539

 Original videos

0.820 (0.680–0.961)

0.833

0.765

0.800

0.801

0.800

0.800

0.599

 Aligned videos

0.905 (0.802–1.000)

0.947

0.690

0.829

0.844

0.829

0.824

0.648

Zeiss dataset

 Images

0.767 (0.620–0.914)

0.750

0.933

0.821

0.852

0.821

0.823

0.643

 Original videos

0.837 (0.713–0.961)

0.826

0.813

0.821

0.823

0.821

0.821

0.633

 Aligned videos

0.919 (0.831–1.000)

0.913

0.933

0.921

0.923

0.921

0.921

0.837

  1. AUC = area under the receiver operating characteristic curve; CI = confidence interval
  2. The bold numbers indicate optimal results