Table 3 Short-term reproducibility of each retinal layer thickness measurement

From: Reproducibility of each retinal layer thickness measurement in epiretinal membrane patients with ectopic inner foveal layers

Parameter 

Group 1

Group 2

 

CV (%)

ICC

Reproducibility limit (μm)

CV (%)

ICC

Reproducibility limit (μm)

CMT

1.49

0.964

21.18

1.70

0.962

19.52

NFL

22.39

0.431

47.05

18.20

0.788

17.82

GCL

13.12

0.550

17.43

10.59

0.834

12.17

IPL

13.37

0.440

17.95

10.65

0.830

11.17

INL

13.21

0.286

18.99

13.27

0.715

16.27

OPL

15.09

0.279

16.59

14.75

0.226

15.86

ONL

11.94

0.503

33.28

10.37

0.439

29.99

  1. CMT = central macular thickness; NFL = nerve fiber layer; GCL = ganglion cell layer; IPL = inner plexiform layer; INL = inner nuclear layer; OPL = outer plexiform layer; ONL = outer nuclear layer