Table 1 Demographic data of the study cases

From: Laboratory evaluation of higher-order aberrations and light scattering in explanted opacified intraocular lenses

Case no. IOL model Labeled power (D) Date of implantation Date of explantation Ageb (years) VA (preop) VA (postop) Microscopic images
1 LS-312-1 Y asph 21.5 12.01.2011 18.07.2018 81 0.5 0.5
2 LS-313 23.2a 2012 28.06.2018 81 0.1 0.4
3 LS-502-1 25.5 09.01.2012 26.06.2018 78 NA NA
4 L-313 19.5 17.11.2014 18.01.2019 67 0.16 0.1
5 LS-502-1 19.5 21.02.2011 03.01.2019 80 0.9 NA
6 L402 24.4a NA 08.05.2019 49 1.25 0.9d
7 L-312 21.9a 07.03.2017 02.05.2019 83 0.63c 0.3c
8 L-402 18.0 12.10.2010 20.02.2019 68 1.0 NA
9 LS-502-1 19.5 23.01.2012 07.05.2019 76 0.6 NA
10 LS-402 23.0 12.12.2011 12.02.2019 86 NA NA
Control L-313 20.0      
  1. IOL= intraocular lens, VA= visual acuity, NA= not available
  2. aThe power measured by a wavefront device as the labeled power was not available;
  3. bPatient’s age at explantation;
  4. cUncorrected visual acuity;
  5. dVisual acuity obtained 1 day after surgery