Skip to main content

Table 1 Summary of the major publications in retinal analysis using DL, grouped by standard multiple-field fundus photography, ultra-wide field photography and smartphone-based photography

From: Different fundus imaging modalities and technical factors in AI screening for diabetic retinopathy: a review

Authors and year of publication

Approach

Training dataset

Validation datasets

Performance

Standard view photography

 Gulshan et al. 2016 [35]

Inception-V3 network

Public

EyePACS and Messidor-2 (> 120,000 images)

Public

EyePACS-1 and Messidor-2 (> 10,000 images)

EyePACS-1

AUC: 0.99

Sensitivity: 90%

Specificity: 98%

Messidor-2

AUC: 0.99

Sensitivity: 87%

Specificity: 99%

 Abràmoff et al. 2016 [46]

AlexNet/VGG network

Public

Messidor-2

Public

Messidor-2 (~ 2000 images)

AUC: 0.98

Sensitivity: 97%

Specificity: 87%

 Ting et al. 2017 [26]

VGGNet-19 network

Proprietary

SiDRP 2010–2013 (> 76,000 images)

Proprietary

SiDRP 14–15 and 10 others (> 112,000 images)

SiDRP 2014–2015

AUC: 0.93

Sensitivity: 91%

Specificity: 92%

Others

AUC range: 0.89 to 0.98

Sensitivity range: 92 to 100%

Specificity: 76 to 92%

 Gargeya et al. 2017 [47]

Customised CNN network

Public EyePACS-1 (> 75,000 images)

Public

EyePACS-1, Messidor-2,E-Ophtha (> 17,000 images)

EyePACS-1

AUC: 0.97

Sensitivity: 94%

Specificity: 96%

Messidor-2 and E-Ophtha

AUC range: 0.83 to 0.95

Sensitivity range: 74 to 93%

Specificity range: 87 to 94%

 Abràmoff et al. 2018 [34]

AlexNet/VGGNet network

Public

Messidor-2

Proprietary

Primary care sites (~ 900 patients)

Sensitivity: 87%

Specificity: 91%

 Keel et al. 2018 [48]

Inception-V3 network

Public

LabelMe (~ 59,000)

Proprietary

Endocrinology outpatient services (96 patients)

Sensitivity: 92%

Specificity: 94%

 Kanagasingam et al. 2018 [49]

Inception-V3 network

Public and proprietary

DiaRetDB1, EyePACS, Australian tele-eye care (30,000 images)

Proprietary

Primary care (~ 200 patients)

Sensitivity: 92%

 Gulshan et al. 2019 [50]

Inception-v4 network

Public

EyePACS and Messidor-2 (> 144,000 images)

Proprietary

Two eye hospitals (~ 6000 images)

AUC range: 0.97 to 0.98

Sensitivity range: 89 to 92%

Specificity range: 92 to 95%

 Raumviboonsuk et al. 2019 [51]

Inception-v4 network

Public

EyePACS and Messidor-2 (> 120,000 images)

Proprietary

Hospitals and health centers (~ 30,000 images)

AUC: 0.99

Sensitivity: 96.9%

Specificity: 95.3%

 Bellemo et al. 2019 [52]

VGGNet/ResNet network

Proprietary

SiDRP 2010–2013 (> 76,000 images)

Proprietary

Mobile screening unit (> 4000 images)

AUC: 0.97

Sensitivity: 92%

Specificity: 89%

Ultra-wide field photography

 Wang et al. 2018 [53]

EyeArt software

–

Proprietary

Eye clinics (~ 1500 images)

AUC: 0.85

Sensitivity: 90%

Specificity: 54%

 Nagasawa at al. 2019 [54]

VGGNet-16 network

Proprietary Hospitals (< 400 images)

Proprietary

Hospitals (< 400 images)

AUC: 0.97

Sensitivity: 95%

Specificity: 97%

Smartphone-based photography

 Rajalakshmi et al. 2018 [55]

EyeArt software

–

Proprietary

Tertiary care diabetes hospital (~ 300 images)

Sensitivity: 96%

Specificity: 80%

 Natarajan et al. 2019 [56]

Remidio software

Inception-V3 network

Public and proprietary

EyePACS and hospitals (> 52,000 images)

Proprietary

Population-based screening (> 4000 images)

Sensitivity range: 96 to 100%

Specificity range: 79 to 88%

 Rogers et al. 2019 [57]

Pegasus software

–

Public and proprietary

IDRiD and research laboratory study (> 6000 images)

AUC range: 89 to 99%

Sensitivity range: 82 to 93%

Specificity range: 82 to 94%