Table 2 Refractive outcomes of IOL power calculation in eyes with no historical data

From: Intraocular lens power calculation in eyes with previous corneal refractive surgery

 

N

MedAE (D)

Mean Error (D)*

% < 0.5 D

Mean ± SD

Range

Barrett True-K No-Hx [33]

30

0.41

−0.20 ± 0.64

−1.55, 1.28

63.3

Barrett True-K No-Hx [34]

104

0.42

−0.07 ± 0.89

−1.86, 2.65

58.7

Haigis-L [30]

170

–

−0.26 ± 1.13

−3.40, 6.34

40.2

Haigis-L [33]

58

0.58

−0.34 ± 0.74

−1.65, 2.86

48.3

Haigis-L [33]

30

0.62

−0.50 ± 0.65

−1.94, 1.03

46.7

Haigis-L [34]

104

0.39

−0.07 ± 0.88

−2.15, 2.04

55.8

Haigis-L [70]

39

0.26

–

–

69.0

OCT [34]

104

0.35

−0.20 ± 0.73

−2.10, 1.33

68.3

OCT [70]

39

0.28

–

–

72.0

Intraoperative aberrometry [70]

39

0.29

–

–

74.0

Ray-tracing [64]

21

0.25

0.13 ± 0.49

−0.85, 1.28

71.4

Shammas No-Hx [30]

170

–

−0.10 ± 1.02

−5.42, 6.16

53.8

Shammas No-Hx [30]

30

0.53

−0.34 ± 0.72

−1.75, 1.46

50.0

Shammas No-Hx [34]

104

0.48

−0.34 ± 0.94

−2.09, 2.99

52.9

  1. MedAE = median absolute error in refraction prediction; SD = standard deviation; D = diopters
  2. *A negative number shows a myopic outcome