Table 3 The correlation between the Binocular and the Monocular estimated values based on spherical equivalent defocus power, astigmatism magnitude, cardinal and oblique astigmatism, and the functional optical zone

From: Corneal functional optical zone under monocular and binocular assessment

Metric

Representation

Average for BE

Range/ Median for BE

Difference between BE and ME

Correlation for BE Vs ME

SE

Fig. 6

0.78 ± 1.30 D

−4.00 to 3.39 D/ 0.68 D

NSSD (p = 0.2)

SS (p < .0001) positive symmetry

Astigmatism (magnitude)

Fig. 7

0.46 ± 0.52 D

0.02 to 2.85 D/ 0.31 D

SSD (p < 0.0005)

SS (p < .0001) positive symmetry

Cardinal astigmatism

Fig. 8

−0.05 ± 0.33 D

−1.41 to 1.01 D/ -0.07 D

NSSD (p = 0.3)

SS (p < .0001) positive symmetry

Oblique astigmatism

Fig. 9

−0.00 ± 0.09 D

− 0.29 to 0.40 D/ -0.00 D

NSSD (p = 0.08)

NSS (p = .1) positive symmetry

FOZ

Fig. 10

6.97 ± 1.34 mm

4.13 to 9.44 mm/ 7.20 m

SSD (p < 0. 0001)

SS (p < .0001) positive symmetry

  1. BE = binocular estimator; ME = monocular estimator; SE = spherical equivalent; Fig. = figure; FOZ = functional optical zone; NSSD = no statistical significant difference; SSD = statistically significant difference; SS = statistical significance