Skip to main content

Table 3 Comparative table showing the postoperative data of patients included in the Lumina intraocular lens group and the monofocal control group

From: Accommodative intraocular lenses: where are we and where we are going

Mean (SD) Range Lumina intraocular lens (N = 61) Monofocal control lens (N = 25) P-value
LogMAR UDVA 0.24 (0.36)
-0.08 to 1.40
0.06 (0.11)
-0.08 to 0.30
0.21
Sphere (D) -0.27 (1.10)
-4.75 to +2.00
+0.52 (0.81)
-1.25 to +1.50
<0.01
Cylinder (D) -1.39 (0.79)
-4.25 to -0.25
-1.02 (0.60)
-2.00 to 0.00
0.17
LogMAR CDVA 0.05 (0.26)
-0.08 to 1.40
0.00 (0.06)
-0.08 to 0.10
0.73
LogRAD UNVA 0.13 (0.14)
0.00 to 0.52
0.35 (0.16)
0.00 to 0.52
<0.01
LogRAD CDNVA 0.12 (0.20)
-0.08 to 1.00
0.37 (0.18)
0.10 to 0.52
<0.01
LogRAD CNVA 0.02 (0.08)
-0.08 to 0.30
0.06 (0.13)
-0.08 to 0.40
0.51
  1. SD = standard deviation, D = diopters, UDVA = uncorrected distance visual acuity, CDVA = corrected distance visual acuity, UNVA = uncorrected near visual acuity, CDNVA = corrected-distance near visual acuity, CNVA = corrected near visual acuity, N = number of cases