From: Seven-year follow-up of posterior chamber phakic intraocular lens with central port design
Mean ± SD | Range [Min, Max] | |
---|---|---|
Age (years) | 31.04 ± 4.89 | [25, 50] |
Refraction sphere (D) | −9.02 ± 2.85 | [−17.50, −4.0] |
Refraction cylinder (D) | −0.65 ± 0.51 | [−1.5, 0] |
Spherical Equivalent (D) | −9.35 ± 2.90.60 | [−18.25, −4.50] |
UDVA (logMAR) | 1.63 ± 0.38 | [0.7, 2.0] |
CDVA (logMAR) | 0.04 ± 0.12 | [0.0, 0.4] |
Minimum Keratometry (D) | 43.26 ± 1.64 | [40.00, 46.00] |
Maximum Keratometry (D) | 44.18 ± 1.69 | [40.78, 47.00] |
Corneal thickness (μm) | 530 ± 37 | [448, 630] |
ACD (mm) | 3.13 ± 0.22 | [2.80, 3.75] |
WTW (mm) | 11.95 ± 0.47 | [10.99, 13.45] |
ATA (mm) | 11.74 ± 0.37 | [11.00, 13.20] |
ECD (cells/ mm2) | 2640 ± 336 | [2000, 3903] |
IOP (mmHg) | 13.02 ± 1.78 | [8, 19] |
ICL sphere (D) | −10.17 ± 2.70 | [−18.0, −5.0] |
ICL size (mm) | 13.10 ± 0.33 | [12.6, 13.7] |